Product : ISaGRAF 3.3
Date : 10-March-2000
File : Force select block dialog box in QLD.htm
Subject : Change the behavior of the QLD editor so that the select block dialog isopen after inserting a new block
Keywords: Block - Selection dialog - LD - Customization
____________________________________________________________________
Normally, with the Quick LD editor, the insertion of a new block leads to an "empty" blank block to be inserted. Then you have to double click on it to select a type of block. If you add the following entry to the ISA.INI file, ISaGRAF will automatically open the block selection box each time a new block is inserted:
[DEBUG]
AutoQldFbSel=1
____________________________________________________________________
Copyright © 1996-2009 ICS Triplex ISaGRAF Inc. All rights reserved.